Property Developer-Builder Contract Spain (Contrato entre Promotor y Constructor)
CONTRATO ENTRE PROMOTOR Y CONSTRUCTOR
Property Developer-Builder Contract
Governed by Ley 38/1999, de 5 de noviembre, de Ordenación de la Edificación (LOE)
1. PARTIES
DEVELOPER (PROMOTOR):
Name: [Promotor Name]
NIF/CIF: [Promotor NIF]
Registered Address: [Promotor Address]
Legal Representative: [Promotor Representative]
CONTRACTOR (CONSTRUCTOR):
Name: [Constructor Name]
NIF/CIF: [Constructor NIF]
Registered Address: [Constructor Address]
Legal Representative: [Constructor Representative]
Site Technical Director (Jefe de Obra): [Jefe de Obra]
2. PROJECT DESCRIPTION
Project: [Project Description]
Building Licence (Licencia de Obra): [Building Licence]
Project Architect: [Architect Name]
Cadastral Reference: [Cadastral Reference]
The Constructor undertakes to execute the works strictly in accordance with the approved architectural project (proyecto de ejecución), the building licence conditions, the Código Técnico de la Edificación (CTE — Real Decreto 314/2006), and all applicable regulations. Any modifications to the approved project require a proyecto modificado approved by the original architect and the Ayuntamiento.
3. CONTRACT PRICE AND PAYMENTS
Contract Price (Precio de Contrata, excl. VAT): [Contract Price]
Price Structure: [Price Structure]
Advance Payment (Anticipo): [Advance Payment], payable upon execution of this contract.
Retention (Retención de Garantía): [Retention Percentage] of each monthly certification, withheld until twelve months after completion.
Monthly certifications (certificaciones de obra) shall be issued by the project architect based on completed works and paid by the Developer within 30 days of issue in accordance with Ley 3/2004, de morosidad. IVA shall apply at the applicable rate under Ley 37/1992 del IVA.
4. CONSTRUCTION TIMELINE
Commencement Date (Fecha de Inicio): [Start Date]
Agreed Completion Date (Fecha de Terminación): [Completion Date]
Delay Penalty (Cláusula Penal): [Delay Penalty], pursuant to Código Civil Article 1152. The penalty is without prejudice to the Developer's right to claim additional damages.
5. WARRANTIES AND LIABILITY (GARANTÍAS Y RESPONSABILIDADES)
The Constructor accepts liability for construction defects in accordance with LOE Article 17: (i) 1 year for finishing defects (daños de terminación); (ii) 3 years for habitability defects (defectos que afecten a la habitabilidad); (iii) 10 years for structural defects (daños de carácter estructural). These periods commence from the Certificado de Recepción de la Obra.
Decennial Insurance (Seguro Decenal): [Decennial Insurer]. The Developer shall obtain and maintain mandatory decennial structural defect insurance under LOE Article 19 before the Certificado Final de Obra is issued.
6. HEALTH AND SAFETY (SEGURIDAD Y SALUD)
Health and Safety Coordinator (CSS-E): [Safety Coordinator], appointed by the Developer pursuant to Real Decreto 1627/1997. The Constructor shall prepare the Plan de Seguridad y Salud (PSS) before commencement and comply with Ley 31/1995 de Prevención de Riesgos Laborales throughout the construction period.
The Constructor shall register all subcontractors in the Registro de Empresas Acreditadas (REA) and maintain the Libro de Subcontratación on site at all times, in compliance with Ley 32/2006, reguladora de la subcontratación en el sector de la construcción.
7. GOVERNING LAW AND JURISDICTION
This contract is governed by Spanish law, principally the Ley de Ordenación de la Edificación (LOE 38/1999), the Código Técnico de la Edificación (CTE — RD 314/2006), and the Código Civil. Disputes shall be resolved before the Juzgado de lo Mercantil or Juzgado de Primera Instancia of the jurisdiction where the building project is located, following mediation under Ley 5/2012.
SIGNATURES
Signed in [Contract City], on [Contract Date].
DEVELOPER (PROMOTOR):
[Promotor Name]
Represented by: [Promotor Representative]
Signature: _________________________ Date: _________________________
CONTRACTOR (CONSTRUCTOR):
[Constructor Name]
Represented by: [Constructor Representative]
Signature: _________________________ Date: _________________________
Developer (Promotor)
________________
Signature
Contractor (Constructor)
________________
Signature
What Is a Property Developer-Builder Contract Spain (Contrato entre Promotor y Constructor)?
A Property Developer-Builder Contract Spain (Contrato entre Promotor y Constructor) under Ley 38/1999, de 5 de noviembre, de Ordenación de la Edificación (LOE) Article 9 is a formal agreement between a property developer (promotor) — the natural or legal person who decides, promotes, programmes, and finances building works — and a construction contractor (constructor) — the company or professional responsible for executing the building project in accordance with the approved architectural project, technical specifications, and building licence granted by the competent Ayuntamiento. The LOE establishes the framework for Spain's construction sector, defining the obligations, rights, and liability regimes of all intervening parties (agentes de la edificación): the promotor, the constructor, the arquitecto director de obra, the arquitecto técnico or aparejador, and any subcontractors.
The Ley de Ordenación de la Edificación (LOE 38/1999) introduced Spain's modern building liability regime, replacing the former civil liability framework under Código Civil Articles 1591–1600 with a structured system of decennial, triennial, and annual warranties (garantías decenal, trienal, and anual). LOE Article 17 establishes the liability periods: ten years for structural defects affecting foundations, beams, or load-bearing elements (daños de carácter estructural); three years for defects affecting habitability (defectos que afecten a la habitabilidad), including weatherproofing, thermal insulation, and acoustic performance under the Documento Básico HR — Protección frente al Ruido of the Código Técnico de la Edificación (CTE); and one year for defects in finishing works (defectos de terminación o acabado).
The Código Técnico de la Edificación (CTE), approved by Real Decreto 314/2006 and substantially updated by Real Decreto 732/2019, establishes mandatory technical requirements for all new buildings in Spain organised into Documentos Básicos (DB): DB-SE (structural safety), DB-SI (fire safety), DB-SUA (safe usage and accessibility), DB-HS (health and sanitation), DB-HR (noise protection), and DB-HE (energy efficiency). The constructor is responsible for executing works in compliance with all applicable CTE requirements, which are incorporated into the approved architectural project. Non-compliance with CTE standards constitutes a construction defect under LOE Article 17 and may trigger liability to the promotor and subsequent purchasers.
The LOE imposes mandatory decennial insurance (seguro decenal) for residential buildings under LOE Article 19 — the promotor must take out insurance covering structural defects for a minimum ten-year period before the Certificado Final de Obra is issued, confirming that purchasers and subsequent owners have direct recourse against the insurer for structural defects regardless of the original parties' financial capacity. The decennial insurance market in Spain is regulated by the Dirección General de Seguros y Fondos de Pensiones (DGSFP) and the policies must comply with Real Decreto 1627/1997 on minimum safety and health requirements at construction sites.
Construction projects in Spain require a building licence (licencia de obra mayor) from the Ayuntamiento where the property is located, obtained by the promotor before construction commences. The licence is granted based on the approved architectural project prepared by a licensed Arquitecto (Arquitecto Superior) and verified by the Colegio Oficial de Arquitectos (COAA). Upon completion, the Certificado Final de Obra (CFO) is issued by the director de obra and director de ejecución de obra and submitted to the Ayuntamiento to obtain the Licencia de Primera Ocupación or Certificado de Primera Ocupación — prerequisite for utilities connection and property registration in the Registro de la Propiedad.
The Real Decreto 1627/1997, de 24 de octubre, sobre disposiciones mínimas de seguridad y salud en obras de construcción (implementing EU Directive 92/57/EEC) requires the appointment of a coordinator de seguridad y salud (CSS) when more than one contractor works simultaneously on site, and mandates preparation of a Plan de Seguridad y Salud (PSS) before construction begins. The promotor bears primary responsibility for designating the CSS and confirming the PSS is prepared and filed with the Autoridad Laboral competente.
When Do You Need a Property Developer-Builder Contract Spain (Contrato entre Promotor y Constructor)?
A Property Developer-Builder Contract Spain is required whenever a promotor (property developer) engages a constructor (building contractor) to execute a construction project on terms governed by the Ley de Ordenación de la Edificación — establishing the technical, economic, and legal framework of the building engagement.
The contract is needed for new residential building projects (obra nueva de vivienda) — whether a single-family detached house (vivienda unifamiliar), a block of flats (edificio plurifamiliar), or a mixed-use development — where the promotor requires a professional constructor to execute the approved architectural project under a building licence (licencia de obra mayor) from the Ayuntamiento.
A Contrato de Promotor y Constructor is required for commercial and industrial building projects — offices, retail premises, warehouses, or industrial facilities — where the LOE's framework of agent responsibilities and warranty periods applies regardless of the non-residential nature of the project.
The contract is needed for rehabilitation and major renovation projects (rehabilitación integral de edificios) meeting the threshold of works affecting the structural, habitability, or energy performance of existing buildings, bringing them within the scope of LOE Article 2 and triggering mandatory decennial insurance under LOE Article 19 for structural interventions.
A Developer-Builder Contract is required before any construction commencement to satisfy requirements of the decennial insurance policy — insurers require the promotor-constructor contract to assess the construction risk, certify the contractor's professional qualifications and financial capacity, and establish the insured construction cost (coste de ejecución material — CEM) as the basis for the insurance premium.
The agreement is also needed to satisfy financing bank requirements — when the promotor finances the construction through a promoter mortgage loan (préstamo promotor), the lending bank typically requires the promotor-constructor contract as due diligence documentation before drawdown, to confirm the construction price, timeline, and contractor qualifications.
Parties in Spain should prepare a Property Developer-Builder Contract Spain (Contrato entre Promotor y Constructor) proactively rather than waiting for a dispute to arise. Courts interpret agreements based on the written terms rather than oral representations. Under the Ley de Arrendamientos Urbanos (LAU) 29/1994, Spanish tenancy law sets minimum duration (5 years individuals, 7 years entities) and deposit requirements. The Código Civil Articles 1445–1541 govern sale of property. The Ley Hipotecaria governs the Registro de la Propiedad. The Ley 5/2019 (LCCI) regulates mortgage lending with mandatory FEIN/FiAE disclosure. The Impuesto sobre Transmisiones Patrimoniales (ITP) applies to property transfers. Where the transaction involves regulated activities, prior approval from the relevant authority may be required before execution.
What to Include in Your Property Developer-Builder Contract Spain (Contrato entre Promotor y Constructor)
A valid Property Developer-Builder Contract Spain under LOE 38/1999 must contain the following essential elements to define the parties' obligations and to satisfy insurance, licensing, and registry requirements.
Identification of Parties: Full legal name, NIF/CIF, registered address, and Registro Mercantil registration details of the promotor (developer) — typically a sociedad limitada or sociedad anónima. For the constructor, the company's NIF/CIF, Registro Mercantil details, professional insurance policy number, and evidence of inscription in the Registro de Contratistas of the competent Autonomous Community if applicable. The constructor's technical director (jefe de obra) must be identified by name and professional college registration number.
Project Description and Technical Documentation: Reference to the approved architectural project (proyecto de ejecución) — architect's name, Colegio Oficial de Arquitectos visa number, building licence number and date, municipal reference, and property cadastral reference. The technical project documents — plans, specifications (pliegos de condiciones), and budget (presupuesto de ejecución material — PEM) — form part of the contract by reference. Any permitted modifications to the approved project during construction must be documented through a proyecto modificado approved by the original architect.
Construction Price and Payment Terms: The agreed contract price (precio de contrata), stated as total lump sum (precio alzado) or measured works basis (precio por unidades de obra), including VAT at the applicable construction rate (10% IVA for residential works under Ley 37/1992 del IVA, Article 91.Uno.3). The payment schedule (calendario de pagos) linked to construction milestones — typically: advance payment (anticipo) upon contract execution, monthly valuations (certificaciones de obra) issued by the architect, and final payment upon Certificado Final de Obra. Payment terms must comply with Ley 3/2004, de medidas de lucha contra la morosidad en las operaciones comerciales (maximum 30-day payment period for subcontractors and suppliers).
Construction Timeline and Programme: The agreed commencement date (fecha de inicio de obras), overall construction period (plazo de ejecución de obras), and completion date (fecha prevista de terminación). The programme of works (programa de trabajos) showing milestone dates for foundations, structure, enclosure, fit-out, and completion. Penalty clauses (cláusulas penales) for delay under Código Civil Article 1152 — typically expressed as a daily or weekly percentage of the contract price per day of delay beyond the agreed completion date, subject to a maximum cap.
Decennial Insurance: The promotor's obligation to obtain and maintain mandatory decennial structural defect insurance (seguro decenal de daños) under LOE Article 19 before Certificado Final de Obra, with the insurance policy number, insurer name, and insured amount (minimum equal to the reconstruction cost of the building) stated or to be incorporated by addendum. The constructor must cooperate with the Control de Calidad inspector (OCA — Organismo de Control Autorizado) appointed by the insurer.
Health and Safety Obligations: Compliance with Real Decreto 1627/1997 — the promotor designates the Coordinador de Seguridad y Salud (CSS) before construction starts; the constructor prepares the Plan de Seguridad y Salud (PSS) and submits it to the CSS and Autoridad Laboral; both parties confirm compliance with Ley 31/1995, de Prevención de Riesgos Laborales throughout the construction period.
Subcontracting Rules: Compliance with Ley 32/2006, reguladora de la subcontratación en el sector de la construcción — the constructor must register all subcontractors in the Registro de Empresas Acreditadas (REA) before they work on site, maintain the Libro de Subcontratación on site at all times, and observe the limits on subcontracting chains established by Ley 32/2006 Article 5.
Warranty and Defects Obligations: The constructor's obligations under LOE Article 17 — one year for finishing defects (daños de terminación), three years for habitability defects (defectos que afecten a la habitabilidad), and ten years for structural defects (daños de carácter estructural) — commencing from the date of the Certificado de Recepción de la Obra signed by the promotor and constructor. The constructor must maintain a retention (retención de garantía) of 5% of the contract price for twelve months post-completion as security against one-year defects.
Forms-legal.com provides this Property Developer-Builder Contract Spain template as a practical starting point. Every construction contract for a project subject to LOE should be reviewed by a qualified abogado specialising in derecho de la construcción and coordinated with the project architect, aparejador, and decennial insurance broker to confirm full compliance with LOE 38/1999, CTE requirements, and the Autonomous Community's building regulations.
Under the Ley de Arrendamientos Urbanos (LAU) 29/1994, Spanish tenancy law sets minimum duration (5 years individuals, 7 years entities) and deposit requirements. The Código Civil Articles 1445–1541 govern sale of property. The Ley Hipotecaria governs the Registro de la Propiedad. The Ley 5/2019 (LCCI) regulates mortgage lending with mandatory FEIN/FiAE disclosure. The Impuesto sobre Transmisiones Patrimoniales (ITP) applies to property transfers.
Cite this page
Reference this free template in an article, syllabus, or research note:
Forms Legal. (2026). Property Developer-Builder Contract Spain (Contrato entre Promotor y Constructor) (Spain) [Legal document template]. Forms Legal. https://forms-legal.com/espana/real-estate/property/property-developer-builder-contract-spain
"Property Developer-Builder Contract Spain (Contrato entre Promotor y Constructor) (Spain)." Forms Legal, 2026, https://forms-legal.com/espana/real-estate/property/property-developer-builder-contract-spain.
@misc{formslegal-property-developer-builder-contract-spain,
author = {{Forms Legal}},
title = {Property Developer-Builder Contract Spain (Contrato entre Promotor y Constructor) (Spain)},
year = {2026},
howpublished = {\url{https://forms-legal.com/espana/real-estate/property/property-developer-builder-contract-spain}},
note = {Free legal document template}
}Frequently Asked Questions
Conforme al artículo 19 de la LOE, el promotor de un edificio de uso residencial debe contratar el seguro decenal de daños materiales obligatorio antes de que se emita el Certificado Final de Obra y el edificio se inscriba en el Registro de la Propiedad como obra nueva terminada. El seguro cubre los daños de carácter estructural que afecten a cimientos, estructura portante y demás elementos estructurales durante un período de diez años desde el Certificado de Recepción de la Obra. El importe mínimo asegurado equivale al coste de reconstrucción del edificio. La aseguradora designa un Organismo de Control Autorizado (OCA) para realizar controles de calidad durante la construcción, emitiendo un Informe de Control de Calidad (ICC) que se incorpora a la póliza. Sin el certificado del seguro decenal, el Notario no puede autorizar la escritura de obra nueva terminada y el Registro de la Propiedad no inscribirá el edificio terminado, bloqueando la venta a terceros. Para los edificios no residenciales, el seguro decenal no es legalmente obligatorio conforme al artículo 19.1 de la LOE, aunque es práctica comercial habitual en edificios de oficinas y uso comercial.
El artículo 17 de la Ley de Ordenación de la Edificación (LOE 38/1999) establece tres plazos de responsabilidad por defectos de construcción en España, computados desde el Certificado de Recepción de la Obra: (1) Diez años (garantía decenal) por daños de carácter estructural —defectos en cimientos, muros de carga, vigas, forjados u otros elementos estructurales que comprometan la resistencia mecánica y la estabilidad del edificio—. Son la categoría más grave y requieren el seguro obligatorio del artículo 19 de la LOE. (2) Tres años (garantía trienal) por defectos que afecten a la habitabilidad —impermeabilización, aislamiento térmico y acústico, o cualquier condición que haga el edificio inadecuado para su uso previsto, incluido el incumplimiento del CTE DB-HS o DB-HR—. (3) Un año (garantía anual) por defectos de terminación o acabado —defectos en revestimientos, alicatados, pintura, carpintería u otros trabajos de terminación—. Las reclamaciones deben presentarse en el plazo de dos años desde el descubrimiento del defecto conforme al plazo de prescripción de la LOE. La responsabilidad del constructor conforme a la LOE es concurrente pero no sustituye a la responsabilidad civil profesional del arquitecto y del aparejador cubierta por sus respectivas pólizas de responsabilidad civil profesional.
La Ley 32/2006, de 18 de octubre, reguladora de la subcontratación en el sector de la construcción impone requisitos estrictos sobre las cadenas de subcontratación en obras de construcción en España. Todas las empresas que trabajen en obras de construcción deben estar inscritas en el Registro de Empresas Acreditadas (REA) que lleva la Autoridad Laboral de la comunidad autónoma competente: la inscripción en el REA acredita que la empresa dispone de capacidad organizativa y de recursos suficientes para cumplir sus obligaciones en materia de seguridad y salud laboral. La cadena de subcontratación está limitada a un máximo de tres niveles bajo el contratista principal: la Ley 32/2006 prohíbe en su artículo 5 que se supere la cadena: promotor → contratista → subcontratista 1 → subcontratista 2 → trabajador autónomo. El constructor debe mantener el Libro de Subcontratación en la obra en todo momento, registrando a todos los subcontratistas y trabajadores autónomos, sus números de inscripción en el REA y el alcance de los trabajos subcontratados. El Libro de Subcontratación debe estar disponible en todo momento para su inspección por la Inspección de Trabajo y Seguridad Social (ITSS). El incumplimiento de las normas de subcontratación constituye una infracción conforme al Real Decreto Legislativo 5/2000 (LISOS).
El precio en un contrato promotor-constructor en España se estructura habitualmente como precio alzado cerrado —precio total fijo con independencia de las mediciones reales, soportando el constructor el riesgo de medición— o como precio por unidades de obra —donde el pago se basa en las mediciones reales a los precios unitarios pactados, soportando el promotor el riesgo de medición—. Las certificaciones de obra mensuales las expide el arquitecto del proyecto sobre la base del porcentaje de obra ejecutada, y el promotor abona cada certificación en el plazo acordado en el contrato (máximo 30 días conforme a la Ley 3/2004, de morosidad). Es habitual un anticipo del 10-20% del precio, a descontar de las certificaciones posteriores. Del importe de cada certificación se retiene habitualmente un 5% hasta los doce meses posteriores a la terminación para cubrir defectos de terminación. El IVA al 10% se aplica a las obras de edificación residencial conforme al artículo 91.Uno.3 de la Ley 37/1992 del IVA; el 21% se aplica a la construcción comercial e industrial. Las fórmulas de revisión de precios del Real Decreto 1098/2001 pueden aplicarse a proyectos de duración superior a doce meses, ajustando el precio del contrato por la inflación de materiales mediante los índices oficiales publicados por el Ministerio de Fomento.
El Real Decreto 1627/1997, de 24 de octubre, que transpone la Directiva 92/57/CEE, establece las disposiciones mínimas de seguridad y salud en las obras de construcción en España. Antes del inicio de los trabajos, el promotor debe designar un Coordinador de Seguridad y Salud durante la elaboración del proyecto (CSS-P) para integrar la seguridad en el diseño, y un Coordinador de Seguridad y Salud durante la ejecución de la obra (CSS-E) cuando concurran en la obra varios contratistas simultáneamente. El CSS-E debe estar en posesión de titulación técnica de arquitecto, ingeniero o aparejador e inscrito en el Colegio Profesional. El promotor debe presentar el Aviso Previo a la Autoridad Laboral antes del inicio de los trabajos en proyectos que superen los 500 días-persona de trabajo o los 30 días laborables con más de 20 trabajadores simultáneos. El contratista principal elabora el Plan de Seguridad y Salud (PSS) antes del inicio, que debe ser aprobado por el CSS-E y aceptado por la Autoridad Laboral. El PSS debe mantenerse en la obra y actualizarse conforme avancen los trabajos. El incumplimiento del RD 1627/1997 constituye infracción grave o muy grave conforme a la Ley 31/1995 de Prevención de Riesgos Laborales, sancionable con multas de hasta 819.780 euros conforme al Real Decreto Legislativo 5/2000 (LISOS).
Los contratos de construcción entre promotores y constructores en España están sujetos al IVA (Impuesto sobre el Valor Añadido) conforme a la Ley 37/1992. Para las obras de edificación de viviendas, se aplica el tipo reducido del 10% conforme al artículo 91.Uno.3 de la Ley del IVA, siempre que las obras sean contratadas directamente por el promotor para uso residencial. Para la construcción comercial, industrial o de oficinas, se aplica el tipo general del 21%. La inversión del sujeto pasivo del artículo 84.Uno.2.º de la Ley 37/1992 se aplica a los contratos de construcción e inmobiliarios entre empresarios inscritos en el IVA en España: el receptor del servicio (promotor) declara el IVA en lugar del proveedor (constructor). En cuanto al impuesto sobre la renta, los beneficios del constructor están sujetos al Impuesto sobre Sociedades (IS) conforme a la Ley 27/2014 al tipo general del 25%. Cuando el promotor contrate a profesionales autónomos individuales, se aplica la retención del 15% del IRPF conforme a la Ley 35/2006. El contrato de construcción en sí no está sujeto normalmente al ITP ni al AJD cuando las partes sean empresarios inscritos en el IVA.
This template is provided for informational purposes only and does not constitute legal advice. Laws vary by jurisdiction and change over time. Consult a qualified attorney for advice specific to your situation.Full disclaimer
Found an error? Let us knowRelated Documents
You may also find these documents useful:
Contrato de Obra España
Contrato de Obra para España — regulado por la Ley de Ordenación de la Edificación (LOE 38/1999) artículo 11, el Código Civil artículos 1588-1600 y el Código Técnico de la Edificación (CTE), que define las obligaciones del contratista, el promotor y la dirección facultativa.
Contrato de Reforma Integral España
Un Contrato de Reforma Integral para España — regulado por el artículo 1588 del Código Civil (contrato de obra por precio alzado) y la Ley 38/1999 LOE para reformas que afecten a elementos estructurales o de habitabilidad, cubriendo el alcance de los trabajos, el precio fijo, el calendario, los hitos de pago y las obligaciones de garantía posobra.
Contrato de Compraventa de Inmueble España
Contrato de Compraventa de Inmueble para España — regulado por el Código Civil, artículo 1445, y la Ley Hipotecaria, para formalizar la venta de bienes inmuebles residenciales o comerciales con título, precio y condiciones hipotecarias.
Acuerdo de Rehabilitación de Edificio (España)
Un Acuerdo de Rehabilitación de Edificio para España — regido por la Ley de Ordenación de la Edificación (LOE) artículo 2, que establece el alcance, las obligaciones y el marco de responsabilidad para obras de renovación y rehabilitación entre el propietario y el contratista.