Skip to main content

Property Developer-Builder Contract Spain (Contrato entre Promotor y Constructor)

Key facts

SpainSpainEnglish (ES)FreePDF & WordUpdated Jun 6, 2026
Legal basisSpainNotarization: Not requiredWitnesses: 0Parties: 2
Property Developer-Builder Contract (Contrato entre Promotor y Constructor)
Property Developer-Builder Contract Spain (Contrato entre Promotor y Constructor)

Contrato de Ejecución de Obra entre Promotor y Constructor

Regulado por la Ley 38/1999, de 5 de noviembre, de Ordenación de la Edificación (LOE)

1. PARTES

PROMOTOR:

Domicilio social: [Promotor Address]

Representante legal: [Promotor Representative]

CONSTRUCTOR:

Domicilio social: [Constructor Address]

Representante legal: [Constructor Representative]

Jefe de obra: [Jefe de Obra]

2. DESCRIPCIÓN DEL PROYECTO

Licencia de obra: [Building Licence]

Arquitecto del proyecto: [Architect Name]

Referencia catastral: [Cadastral Reference]

El constructor se compromete a ejecutar las obras con estricta sujeción al proyecto de ejecución aprobado, a las condiciones de la licencia de obra, al Código Técnico de la Edificación (CTE — Real Decreto 314/2006) y a toda la normativa aplicable. Cualquier modificación del proyecto aprobado requerirá un proyecto modificado aprobado por el arquitecto original y por el Ayuntamiento.

3. PRECIO DE CONTRATA Y PAGOS

Precio de contrata (sin IVA): [Contract Price]

Modalidad del precio: [Price Structure]

Anticipo: [Advance Payment], pagadero a la firma de este contrato.

Retención de garantía: [Retention Percentage] de cada certificación mensual, retenido hasta doce meses después de la terminación.

Las certificaciones de obra serán emitidas por el arquitecto del proyecto en función de las obras ejecutadas y abonadas por el promotor en el plazo de 30 días desde su emisión, conforme a la Ley 3/2004, de morosidad. El IVA se aplicará al tipo correspondiente conforme a la Ley 37/1992 del IVA.

4. PLAZOS DE EJECUCIÓN

Fecha de inicio: [Start Date]

Fecha de terminación acordada: [Completion Date]

Cláusula penal por retraso: [Delay Penalty], conforme al artículo 1152 del Código Civil. La penalización se entiende sin perjuicio del derecho del promotor a reclamar daños y perjuicios adicionales.

5. GARANTÍAS Y RESPONSABILIDADES

El constructor asume la responsabilidad por los defectos constructivos conforme al artículo 17 de la LOE: (i) 1 año por daños de terminación; (ii) 3 años por defectos que afecten a la habitabilidad; (iii) 10 años por daños de carácter estructural. Estos plazos se computan desde el Certificado de Recepción de la Obra.

Seguro decenal: [Decennial Insurer]. El promotor deberá contratar y mantener el seguro decenal obligatorio de daños estructurales conforme al artículo 19 de la LOE antes de la emisión del Certificado Final de Obra.

6. SEGURIDAD Y SALUD

Coordinador de seguridad y salud (CSS-E): [Safety Coordinator], designado por el promotor conforme al Real Decreto 1627/1997. El constructor elaborará el Plan de Seguridad y Salud (PSS) antes del inicio de las obras y cumplirá la Ley 31/1995 de Prevención de Riesgos Laborales durante todo el período de ejecución.

El constructor deberá inscribir a todos los subcontratistas en el Registro de Empresas Acreditadas (REA) y mantener el Libro de Subcontratación en obra en todo momento, en cumplimiento de la Ley 32/2006, reguladora de la subcontratación en el sector de la construcción.

7. LEY APLICABLE Y JURISDICCIÓN

Este contrato se rige por la legislación española, principalmente la Ley de Ordenación de la Edificación (LOE 38/1999), el Código Técnico de la Edificación (CTE — RD 314/2006) y el Código Civil. Las controversias se resolverán ante el Juzgado de lo Mercantil o el Juzgado de Primera Instancia del partido judicial donde se ubique la obra, tras intentar la mediación conforme a la Ley 5/2012.

FIRMAS

PROMOTOR:

Representado por: [Promotor Representative]

Firma: _________________________ Fecha: _________________________

CONSTRUCTOR:

Firma: _________________________ Fecha: _________________________

Promotor

________________

Signature

Constructor

________________

Signature

Maintained by Vladislav Sergienko, Founder·Template last modified: ·Report an error

What Is a Property Developer-Builder Contract Spain (Contrato entre Promotor y Constructor)?

A Property Developer-Builder Contract Spain (Contrato entre Promotor y Constructor) under Ley 38/1999, de 5 de noviembre, de Ordenación de la Edificación (LOE) Article 9 is a formal agreement between a property developer (promotor) — the natural or legal person who decides, promotes, programmes, and finances building works — and a construction contractor (constructor) — the company or professional responsible for executing the building project in accordance with the approved architectural project, technical specifications, and building licence granted by the competent Ayuntamiento. The LOE establishes the framework for Spain's construction sector, defining the obligations, rights, and liability regimes of all intervening parties (agentes de la edificación): the promotor, the constructor, the arquitecto director de obra, the arquitecto técnico or aparejador, and any subcontractors.

The Ley de Ordenación de la Edificación (LOE 38/1999) introduced Spain's modern building liability regime, replacing the former civil liability framework under Código Civil Articles 1591–1600 with a structured system of decennial, triennial, and annual warranties (garantías decenal, trienal, and anual). LOE Article 17 establishes the liability periods: ten years for structural defects affecting foundations, beams, or load-bearing elements (daños de carácter estructural); three years for defects affecting habitability (defectos que afecten a la habitabilidad), including weatherproofing, thermal insulation, and acoustic performance under the Documento Básico HR — Protección frente al Ruido of the Código Técnico de la Edificación (CTE); and one year for defects in finishing works (defectos de terminación o acabado).

The Código Técnico de la Edificación (CTE), approved by Real Decreto 314/2006 and substantially updated by Real Decreto 732/2019, establishes mandatory technical requirements for all new buildings in Spain organised into Documentos Básicos (DB): DB-SE (structural safety), DB-SI (fire safety), DB-SUA (safe usage and accessibility), DB-HS (health and sanitation), DB-HR (noise protection), and DB-HE (energy efficiency). The constructor is responsible for executing works in compliance with all applicable CTE requirements, which are incorporated into the approved architectural project. Non-compliance with CTE standards constitutes a construction defect under LOE Article 17 and may trigger liability to the promotor and subsequent purchasers.

The LOE imposes mandatory decennial insurance (seguro decenal) for residential buildings under LOE Article 19 — the promotor must take out insurance covering structural defects for a minimum ten-year period before the Certificado Final de Obra is issued, confirming that purchasers and subsequent owners have direct recourse against the insurer for structural defects regardless of the original parties' financial capacity. The decennial insurance market in Spain is regulated by the Dirección General de Seguros y Fondos de Pensiones (DGSFP) and the policies must comply with Real Decreto 1627/1997 on minimum safety and health requirements at construction sites.

Construction projects in Spain require a building licence (licencia de obra mayor) from the Ayuntamiento where the property is located, obtained by the promotor before construction commences. The licence is granted based on the approved architectural project prepared by a licensed Arquitecto (Arquitecto Superior) and verified by the Colegio Oficial de Arquitectos (COAA). Upon completion, the Certificado Final de Obra (CFO) is issued by the director de obra and director de ejecución de obra and submitted to the Ayuntamiento to obtain the Licencia de Primera Ocupación or Certificado de Primera Ocupación — prerequisite for utilities connection and property registration in the Registro de la Propiedad.

The Real Decreto 1627/1997, de 24 de octubre, sobre disposiciones mínimas de seguridad y salud en obras de construcción (implementing EU Directive 92/57/EEC) requires the appointment of a coordinator de seguridad y salud (CSS) when more than one contractor works simultaneously on site, and mandates preparation of a Plan de Seguridad y Salud (PSS) before construction begins. The promotor bears primary responsibility for designating the CSS and confirming the PSS is prepared and filed with the Autoridad Laboral competente.

When Do You Need a Property Developer-Builder Contract Spain (Contrato entre Promotor y Constructor)?

A Property Developer-Builder Contract Spain is required whenever a promotor (property developer) engages a constructor (building contractor) to execute a construction project on terms governed by the Ley de Ordenación de la Edificación — establishing the technical, economic, and legal framework of the building engagement.

The contract is needed for new residential building projects (obra nueva de vivienda) — whether a single-family detached house (vivienda unifamiliar), a block of flats (edificio plurifamiliar), or a mixed-use development — where the promotor requires a professional constructor to execute the approved architectural project under a building licence (licencia de obra mayor) from the Ayuntamiento.

A Contrato de Promotor y Constructor is required for commercial and industrial building projects — offices, retail premises, warehouses, or industrial facilities — where the LOE's framework of agent responsibilities and warranty periods applies regardless of the non-residential nature of the project.

The contract is needed for rehabilitation and major renovation projects (rehabilitación integral de edificios) meeting the threshold of works affecting the structural, habitability, or energy performance of existing buildings, bringing them within the scope of LOE Article 2 and triggering mandatory decennial insurance under LOE Article 19 for structural interventions.

A Developer-Builder Contract is required before any construction commencement to satisfy requirements of the decennial insurance policy — insurers require the promotor-constructor contract to assess the construction risk, certify the contractor's professional qualifications and financial capacity, and establish the insured construction cost (coste de ejecución material — CEM) as the basis for the insurance premium.

The agreement is also needed to satisfy financing bank requirements — when the promotor finances the construction through a promoter mortgage loan (préstamo promotor), the lending bank typically requires the promotor-constructor contract as due diligence documentation before drawdown, to confirm the construction price, timeline, and contractor qualifications.

Parties in Spain should prepare a Property Developer-Builder Contract Spain (Contrato entre Promotor y Constructor) proactively rather than waiting for a dispute to arise. Courts interpret agreements based on the written terms rather than oral representations. Under the Ley de Arrendamientos Urbanos (LAU) 29/1994, Spanish tenancy law sets minimum duration (5 years individuals, 7 years entities) and deposit requirements. The Código Civil Articles 1445–1541 govern sale of property. The Ley Hipotecaria governs the Registro de la Propiedad. The Ley 5/2019 (LCCI) regulates mortgage lending with mandatory FEIN/FiAE disclosure. The Impuesto sobre Transmisiones Patrimoniales (ITP) applies to property transfers. Where the transaction involves regulated activities, prior approval from the relevant authority may be required before execution.

What to Include in Your Property Developer-Builder Contract Spain (Contrato entre Promotor y Constructor)

A valid Property Developer-Builder Contract Spain under LOE 38/1999 must contain the following essential elements to define the parties' obligations and to satisfy insurance, licensing, and registry requirements.

Identification of Parties: Full legal name, NIF/CIF, registered address, and Registro Mercantil registration details of the promotor (developer) — typically a sociedad limitada or sociedad anónima. For the constructor, the company's NIF/CIF, Registro Mercantil details, professional insurance policy number, and evidence of inscription in the Registro de Contratistas of the competent Autonomous Community if applicable. The constructor's technical director (jefe de obra) must be identified by name and professional college registration number.

Project Description and Technical Documentation: Reference to the approved architectural project (proyecto de ejecución) — architect's name, Colegio Oficial de Arquitectos visa number, building licence number and date, municipal reference, and property cadastral reference. The technical project documents — plans, specifications (pliegos de condiciones), and budget (presupuesto de ejecución material — PEM) — form part of the contract by reference. Any permitted modifications to the approved project during construction must be documented through a proyecto modificado approved by the original architect.

Construction Price and Payment Terms: The agreed contract price (precio de contrata), stated as total lump sum (precio alzado) or measured works basis (precio por unidades de obra), including VAT at the applicable construction rate (10% IVA for residential works under Ley 37/1992 del IVA, Article 91.Uno.3). The payment schedule (calendario de pagos) linked to construction milestones — typically: advance payment (anticipo) upon contract execution, monthly valuations (certificaciones de obra) issued by the architect, and final payment upon Certificado Final de Obra. Payment terms must comply with Ley 3/2004, de medidas de lucha contra la morosidad en las operaciones comerciales (maximum 30-day payment period for subcontractors and suppliers).

Construction Timeline and Programme: The agreed commencement date (fecha de inicio de obras), overall construction period (plazo de ejecución de obras), and completion date (fecha prevista de terminación). The programme of works (programa de trabajos) showing milestone dates for foundations, structure, enclosure, fit-out, and completion. Penalty clauses (cláusulas penales) for delay under Código Civil Article 1152 — typically expressed as a daily or weekly percentage of the contract price per day of delay beyond the agreed completion date, subject to a maximum cap.

Decennial Insurance: The promotor's obligation to obtain and maintain mandatory decennial structural defect insurance (seguro decenal de daños) under LOE Article 19 before Certificado Final de Obra, with the insurance policy number, insurer name, and insured amount (minimum equal to the reconstruction cost of the building) stated or to be incorporated by addendum. The constructor must cooperate with the Control de Calidad inspector (OCA — Organismo de Control Autorizado) appointed by the insurer.

Health and Safety Obligations: Compliance with Real Decreto 1627/1997 — the promotor designates the Coordinador de Seguridad y Salud (CSS) before construction starts; the constructor prepares the Plan de Seguridad y Salud (PSS) and submits it to the CSS and Autoridad Laboral; both parties confirm compliance with Ley 31/1995, de Prevención de Riesgos Laborales throughout the construction period.

Subcontracting Rules: Compliance with Ley 32/2006, reguladora de la subcontratación en el sector de la construcción — the constructor must register all subcontractors in the Registro de Empresas Acreditadas (REA) before they work on site, maintain the Libro de Subcontratación on site at all times, and observe the limits on subcontracting chains established by Ley 32/2006 Article 5.

Warranty and Defects Obligations: The constructor's obligations under LOE Article 17 — one year for finishing defects (daños de terminación), three years for habitability defects (defectos que afecten a la habitabilidad), and ten years for structural defects (daños de carácter estructural) — commencing from the date of the Certificado de Recepción de la Obra signed by the promotor and constructor. The constructor must maintain a retention (retención de garantía) of 5% of the contract price for twelve months post-completion as security against one-year defects.

Forms-legal.com provides this Property Developer-Builder Contract Spain template as a practical starting point. Every construction contract for a project subject to LOE should be reviewed by a qualified abogado specialising in derecho de la construcción and coordinated with the project architect, aparejador, and decennial insurance broker to confirm full compliance with LOE 38/1999, CTE requirements, and the Autonomous Community's building regulations.

Under the Ley de Arrendamientos Urbanos (LAU) 29/1994, Spanish tenancy law sets minimum duration (5 years individuals, 7 years entities) and deposit requirements. The Código Civil Articles 1445–1541 govern sale of property. The Ley Hipotecaria governs the Registro de la Propiedad. The Ley 5/2019 (LCCI) regulates mortgage lending with mandatory FEIN/FiAE disclosure. The Impuesto sobre Transmisiones Patrimoniales (ITP) applies to property transfers.

Cite this page

CC BY 4.0 · free to cite

Reference this free template in an article, syllabus, or research note:

APA
Forms Legal. (2026). Property Developer-Builder Contract Spain (Contrato entre Promotor y Constructor) (Spain) [Legal document template]. Forms Legal. https://forms-legal.com/espana/real-estate/property/property-developer-builder-contract-spain
MLA
"Property Developer-Builder Contract Spain (Contrato entre Promotor y Constructor) (Spain)." Forms Legal, 2026, https://forms-legal.com/espana/real-estate/property/property-developer-builder-contract-spain.
Chicago
Forms Legal. "Property Developer-Builder Contract Spain (Contrato entre Promotor y Constructor) (Spain)." Forms Legal, 2026. https://forms-legal.com/espana/real-estate/property/property-developer-builder-contract-spain.
BibTeX
@misc{formslegal-property-developer-builder-contract-spain,
  author       = {{Forms Legal}},
  title        = {Property Developer-Builder Contract Spain (Contrato entre Promotor y Constructor) (Spain)},
  year         = {2026},
  howpublished = {\url{https://forms-legal.com/espana/real-estate/property/property-developer-builder-contract-spain}},
  note         = {Free legal document template}
}
Wikipedia
{{cite web |title=Property Developer-Builder Contract Spain (Contrato entre Promotor y Constructor) (Spain) |website=Forms Legal |publisher=Forms Legal |date=2026 |url=https://forms-legal.com/espana/real-estate/property/property-developer-builder-contract-spain}}
RIS
TY  - ELEC
T1  - Property Developer-Builder Contract Spain (Contrato entre Promotor y Constructor) (Spain)
T2  - Forms Legal
PB  - Forms Legal
PY  - 2026
UR  - https://forms-legal.com/espana/real-estate/property/property-developer-builder-contract-spain
ER  - 
Forms LegalUpdated 2026-06-06.bib.ris

Frequently Asked Questions

Statute-referenced template — Template last modified June 2026

This template is provided for informational purposes only and does not constitute legal advice. Laws vary by jurisdiction and change over time. Consult a qualified attorney for advice specific to your situation.Full disclaimer

Found an error? Let us know