---
title: "Bushfire Attack Level (BAL) Assessment Report"
url: "https://forms-legal.com/australia/real-estate/property/bushfire-attack-level-bal-assessment-report"
description: "A Bushfire Attack Level (BAL) Assessment Report in Australia records the bushfire attack level assessment of a site under AS 3959-2018 (Construction of buildings in bushfire-prone areas): the vegetation, distance and slope findings, the BAL rating that results and the construction requirements that follow from it."
language: "en"
jurisdiction: "Australia"
category: "Real Estate / Property & Deeds"
primaryStatute: "Planning and Environment Act 1987 (Vic)"
dateModified: "2026-11-01"
maintainer: "Vladislav Sergienko, founder (not a lawyer)"
---

# Bushfire Attack Level (BAL) Assessment Report

- Australia · Real Estate / Property & Deeds
- Legal basis: Planning and Environment Act 1987 (Vic)

## What Is a Bushfire Attack Level (BAL) Assessment Report?

A Bushfire Attack Level (BAL) Assessment Report in Australia records the bushfire attack level assessment of a site under AS 3959-2018 (Construction of buildings in bushfire-prone areas): the vegetation, distance and slope findings, the BAL rating that results and the construction requirements that follow from it. The report supports planning and building approvals in bushfire-prone areas, including planning permits under the Planning and Environment Act 1987 (Vic) and development consent under the Environmental Planning and Assessment Act 1979 (NSW).

The BAL scale ranges from BAL-LOW (negligible risk, no special construction requirements) through BAL-12.5, BAL-19, BAL-29, BAL-40 (ascending levels of risk requiring progressively more stringent construction standards), to BAL-FZ (Flame Zone — the most extreme category, where direct flame contact is expected and the most onerous construction requirements apply or development may not be permitted). The BAL rating determines the bushfire construction requirements for a building under Section 3 to Section 9 of AS 3959-2018.

The BAL determination methodology involves four key steps: (1) identifying and classifying the type and arrangement of bushfire vegetation on and adjacent to the site using the vegetation classification tables in AS 3959-2018; (2) measuring the horizontal distance from the proposed building footprint to the nearest classified vegetation; (3) determining the effective slope of the land under the vegetation (which affects how fire travels); and (4) applying the BAL determination tables in AS 3959-2018 (Section 2) to arrive at a BAL rating for each elevation, with the highest elevation rating becoming the overall site BAL.

BAL assessments are required by state and territory planning legislation for development in designated Bushfire Prone Areas. In Victoria, properties with a Bushfire Management Overlay (BMO) or Wildfire Management Overlay (WMO) require a BAL assessment and a Bushfire Management Statement as part of a planning permit application. In New South Wales, properties on the NSW Rural Fire Service Bushfire Prone Land Map require a BAL assessment and a compliant Bushfire Attack Level Certificate for a construction certificate or complying development certificate.

## When Do You Need a Bushfire Attack Level (BAL) Assessment Report?

A BAL Assessment Report is required in a wide range of circumstances involving development in bushfire-prone areas across Australia.

New residential construction: The most common reason for a BAL assessment is the construction of a new dwelling on land in a bushfire-prone area. Before a building permit (building approval in Queensland, construction certificate in NSW) can be issued for a new dwelling in a bushfire-prone area, a BAL assessment must be conducted and the construction must comply with the requirements of AS 3959-2018 for the determined BAL rating.

Subdivision and development applications: When land in a bushfire-prone area is subdivided to create new lots, each proposed new lot must be assessed for bushfire risk. Planning permits for subdivision in bushfire-prone areas typically include conditions relating to minimum lot size, access, water supply, and vegetation management — all of which are informed by the BAL assessment.

Renovations and extensions: Significant extensions to existing buildings in bushfire-prone areas may require a BAL assessment and compliance with AS 3959-2018 for the new portion of the building. The requirements depend on the extent of the renovation and the relevant state planning and building legislation.

Change of use: Changing the use of a building in a bushfire-prone area — for example, converting a shed into a dwelling, or a guesthouse into a permanent residence — may trigger a BAL assessment requirement under the relevant planning scheme.

Due diligence for property purchase: Prospective purchasers of land in bushfire-prone areas often commission a BAL assessment as part of pre-purchase due diligence to understand the construction standards that will apply to any future development and the implications of the BAL rating for insurance and property value.

Insurance: Some insurers require a BAL assessment report as part of the underwriting process for properties in bushfire-prone areas, particularly for high BAL ratings (BAL-40 and BAL-FZ).

## What to Include in Your Bushfire Attack Level (BAL) Assessment Report

A technically competent BAL Assessment Report under AS 3959-2018 must include specific elements to be accepted by planning authorities and building certifiers.

Assessor qualifications: The report must be prepared by a person with appropriate qualifications and competence to conduct BAL assessments. Different states have different requirements — in Victoria, a BPAD (Bushfire Planning and Design) Level 3 accredited practitioner is typically required for complex assessments. In NSW, a BAL Certificate for planning purposes requires the relevant qualifications as specified by the NSW Rural Fire Service guidelines.

Site inspection: A physical inspection of the site is required — a desk-top assessment alone is generally not sufficient. The inspection should document the vegetation types, arrangement, condition, and distances observed, with supporting photographs.

Vegetation classification: The vegetation on and adjacent to the site must be classified in accordance with Table 2.3 of AS 3959-2018. The standard identifies seven vegetation classes (A through G): Class A Forest, Class B Woodland, Class C Shrubland, Class D Scrub, Class E Mallee/Mulga, Class F Rainforest and Class G Grassland. Accurately classifying the vegetation is the most technically demanding part of a BAL assessment.

Distance measurement: Accurate measurement of the distance from the proposed building footprint to the nearest classified vegetation edge is critical. The distance is the horizontal distance (not slope distance) in metres.

Slope determination: The effective slope — the slope of the land beneath and uphill of the classified vegetation — must be measured in degrees. Slope directly affects fire behaviour and therefore the BAL rating.

BAL determination tables: The BAL rating is determined by applying the relevant table from AS 3959-2018 (Section 2) using the vegetation class, the distance, and the slope. The assessment must be conducted for each elevation of the building site independently, with the highest resulting BAL becoming the overall site BAL.

Construction requirements: The report should summarise the key construction requirements applicable to the determined BAL under the relevant sections of AS 3959-2018.

APZ and vegetation management: Asset Protection Zone (APZ) requirements and recommendations for vegetation management should be included, consistent with the relevant state's bushfire planning guidelines.

## Sources & Citations

- [Planning and Environment Act 1987](https://www.legislation.gov.au/)

## Frequently Asked Questions

### What are the six BAL ratings and what construction requirements apply to each?

The six Bushfire Attack Level (BAL) ratings under AS 3959-2018 are, from lowest to highest risk: BAL-LOW (negligible risk — no special construction requirements apply); BAL-12.5 (low risk — ember attack with low heat flux: specific requirements for roof, gutters, vents, decks, and windows); BAL-19 (moderate risk — ember attack with burning debris and low flame contact: more stringent requirements for walls, roof, and openings); BAL-29 (high risk — ember attack with burning debris and higher radiant heat: stricter requirements for walls, windows, and subfloor); BAL-40 (very high risk — ember attack with radiant heat above 29 kW/m2 and up to 40 kW/m2, with possible exposure to flames: specific requirements for all elements); BAL-FZ (Flame Zone — extreme risk — radiant heat above 40 kW/m2 and direct flame contact expected: the most stringent requirements, including use of non-combustible materials throughout, and development may not be permitted in some states at this BAL rating). Each BAL rating corresponds to a section of AS 3959-2018 that specifies the construction requirements for that level of risk.

### Who can conduct a BAL assessment in Australia?

The qualification requirements for conducting a BAL assessment vary by state and territory. In Victoria, a BAL assessment and Bushfire Management Statement for a planning permit application must typically be prepared by a person accredited to BPAD Level 3 under the Bushfire Planning and Design accreditation scheme managed by Fire Protection Association Australia. In New South Wales, the NSW Rural Fire Service's Planning for Bush Fire Protection guidelines specify who may prepare a Bushfire Threat Assessment and associated documentation. In Queensland, a BAL assessment may be conducted by a suitably qualified person as defined by the Queensland Development Code and Queensland Fire and Emergency Services guidelines. In most states, a building certifier, town planner, or architect with appropriate bushfire training can conduct straightforward BAL assessments, while complex assessments (particularly at BAL-40 or BAL-FZ) should be referred to specialist bushfire consultants.

### Can a BAL rating be reduced through vegetation management?

Yes. The BAL rating is determined by the type of classified vegetation, the distance from the building to the vegetation, and the slope. If vegetation is removed or managed to reduce its fuel load and classified type, the BAL rating may decrease. For example, if grassland between the building and bushfire vegetation is managed as a mown lawn (removing it from the classified vegetation category), the effective distance to classified vegetation increases, which may reduce the BAL rating. Establishing and maintaining an Asset Protection Zone (APZ) around a building typically involves managing vegetation to 'Low Threat' standard, which can reduce or eliminate classified vegetation within the APZ and thereby improve the BAL rating. However, vegetation management on private land may require council or state government approval, and management of vegetation in designated conservation areas is often restricted.

### How does a BAL rating affect building insurance in Australia?

A high BAL rating (BAL-40 or BAL-FZ) can significantly affect the availability and cost of building insurance. Some insurers decline to cover properties at BAL-FZ because of the extreme risk of total destruction in a major bushfire. Properties at BAL-40 may attract higher premiums and may require specific construction standards to be verified before insurance is offered. After major bushfire events — such as the 2009 Black Saturday fires in Victoria and the 2019-20 Black Summer fires — many insurers tightened their underwriting criteria for bushfire-prone properties. Property owners in high BAL areas should disclose the BAL rating to their insurer as part of the insurance application process. Non-disclosure of known material facts (including a high BAL rating) can be grounds for an insurer to decline or reduce a claim.

### Do I need a lawyer to create a Bushfire Attack Level (BAL) Assessment Report in Australia?

A Bushfire Attack Level (BAL) Assessment Report does not legally require a lawyer in Australia, and individuals and businesses may draft and execute the document independently. No Australian statute requires a lawyer to prepare a BAL assessment report. However, seeking independent legal advice from a qualified Australia lawyer is recommended for transactions involving substantial financial value, complex regulatory requirements, or cross-border elements where multiple legal jurisdictions may apply. A lawyer can verify that the document complies with all applicable statutory requirements, identify potential risks specific to the transaction, and confirm that the terms adequately protect the interests of all parties involved. Disputes arising from this type of document are generally heard by the courts or civil and administrative tribunals of the relevant state or territory. Professional legal review is particularly advisable where the document will be submitted to government agencies or used as evidence in legal proceedings.

Fillable version (PDF or Word): [Download the free template](https://forms-legal.com/australia/real-estate/property/bushfire-attack-level-bal-assessment-report)

General information, not legal advice — see our [accuracy & editorial policy](https://forms-legal.com/accuracy-policy). Confirm the cited law is current before relying on it.
